Basic Info.

Model NO.:V10, V10F,V10P, V20, V20F, V20P,V2010F/P,V2020F/P
Acting Form:Double-Acting
Type:Vane Pump
Displacement:Variable Pump
Performance:No Blocking
Pressure:Max:17.2MPa
Dis.:3.3~42.50ml/R
Speed:Max:2400~4800r/Min
Service:Trucks,Automobile,Medium-Sized,Heavy Vehicles
Export Markets:Global

Additional Info.

Trademark:HNGM
Packing:Carton
Standard:Vane pump
Origin:China
HS Code:841360
Production Capacity:15000 PCS/Month

Product Description

VICKERS V10, V20, V2010, V2020 FIXED DISPLACEMENT VANE PUMP


Features:

1. V10 and V20 Series are fixed displacement and balanced type vane pump. With compact sizes, they are available in single pumps and double pumps for both industrial and mobile application.

2. The vane design with self compensation for wear and clearances makes volumetric efficiency of pump nearly constant over the service lift. (the vane always adjust its orbit to contact with the cam ring, even though wear occurs between the cam ring and vane tips)

3. The vane pump is not damaged at low speed and high pressure operation because pumping action does not start until the speed is high enough for the vane to through out. With hydraulically balanced design, the bearing is externally loaded only. Therefore, the pump requires minimized maintenance with long service life.

4. The inlet or outlet ports can be rotated through increments of 90° In relation to each other, providing application flexibility and easy installation.

5. With optional flow control and priority valve covers, the pump can be used in more applications. The flow control cover can limit the flow to the primary circuit at the required flow rate, while diverts remaining flow to the tank. The priority valve cover maintains a constant flow to the primary circuit, while diverts remaining flow to the secondary circuit. Each cover comes with a relief valve to limits the maximum pressure of the primary circuit.

Handing:

1. For maximum service life, the pump should be protected from contamination. Filtering fluid before filling and during operation to maintain or exceed ISO cleanliness code 17/14. Replaceable element should be changed as filter supplier instructions.

2. The drive shaft must align with the power source shaft. Avoiding shaft end thrust and applications that impose radial loading.

3. The start-up procedures should be as follows:
-Check the rotation of power source to match the rotation of pump.

-Check inlet and outlet ports to assure all connections are properly installed and check all mounting bolts and flanges to assure all are tight and properly aligned.

-Fill pump with fluid through the outlet port if the pump is mounted above the fluid level. The spline shaft models also need to be lubricated with an anti-fretting grease or similar lubricant.

-Place all controls in the neutral position so the pump is unloaded during initial start-up.

-Bleed off entrapped air from outlet circuit until a steady output flow is observed.

If you want more detail about our products, contact us.
Model SeriesRing Size Delivery at 1200 r/min & 7 bar(100 psi) UsgpmGeometric Displacement cm3/r (in3/r)Delivery at 1500 r/min & 7 bar(100psi) L/min (Usgpm)Maximum Pressure    bar(psi)Maximum Speed      rpmMinimum Speed        rpmWeight    kg(lb)
V10      V10F V10P13.3 (0.02)4.70 (1.25)172 (2500)48006504.5 - 6.8 (10 - 15)
26.6 (0.40)9.40 (2.50)172 (2500)4500650
39.8 (0.60)14.20 (3.75)172 (2500)4000650
413.1 (0.80)18.90 (5.00)172 (2500)3400650
516.4 (1.00)23.60 (6.25)172 (2500)3200650
619.5 (1.19)28.40 (7.50)152 (2200)3000650
722.8 (1.39)33.10 (8.75)138 (2000)2800650
V20      V20F V20P619.5 (1.19)28.39 (7.50)172 (2500)34006507.3 - 8.2 (16 - 18)
722.8 (1.39)33.11 (8.75)172 (2500)3000650
826.5 (1.62)37.85 (10.00)172 (2500)2800650
929.7 (1.81)42.57 (11.25)172 (2500)2800650
1136.4 (2.22)52.04 (13.75)172 (2500)2500650
1239.0 (2.38)56.77 (15.00)152 (2200)2400650
1342.4 (2.59)61.50 (16.25)152 (2200)2400650


Double Pump Operating Specifications

Vickers Vane Pump (V10, V20, V2010, V2020)

Supplier Profile
  • Henan General Machinery Imp. & Exp. Co., Ltd.
  • Audited Supplier
  • Henan, China
  • Business Type: Manufacturer, Trading Company
  • Main Products: Hydraulic Pump, Hydraulic Component, Rexroth Piston Pump, Vickers Yuken Denison Tokimec Pump, Sauer Eaton Charlynn Orbit Motor, Caterpillar Rexroth Liebheer Pistorotary, Oml/ Omm/Omp/ OMR/ Omh Orbit Motor, Omew/ Oms/ Omt/Omv / Tmt Orbit Motor, S T Genroler H Genrotor
  • OEM/ODM Service: Yes
Send your inquiry directly to this supplier
Avatar
Ms. Alice Shao
Salesman
*From
To Ms. Alice Shao
*Message
Enter between 20 to 4,000 characters.
This is not what you are looking for? Post a Sourcing Request Now
Find Similar Products By Category: